Design · Supply · Installation — 10 kVA to 500 kVA

UPS Battery Banks India — Design, Supply & Installation

Sukhai UPS designs, supplies, and installs custom VRLA battery banks for large UPS systems — from 10 kVA to 500 kVA+. We handle battery string calculations, Exide / Quanta / Leoch battery procurement, cabinet supply, intercell cabling, and commissioning. Serving data centres, hospitals, industrial facilities, and commercial buildings across India.

Call +91-98208-43000
25+
Years of Experience
5,000+
Clients Served
50+
Cities Covered
4.9★
Average Rating
Battery Bank Basics

What Is a UPS Battery Bank?

Understanding external battery banks — how they extend UPS backup time for critical applications.

External Battery Extension

Most large UPS systems have an external battery port that connects to one or more external battery cabinets. Each cabinet contains multiple VRLA batteries wired in series to match the UPS DC bus voltage. By connecting additional cabinets, backup time can be extended from 5 minutes to 30, 60, or even 120 minutes depending on load and battery capacity.

Series and Parallel Strings

Batteries are connected in series to build the required string voltage (e.g., 20 × 12V = 240V string for a 240V DC bus UPS). Multiple strings are connected in parallel to increase total Ah capacity and hence backup time. The total energy stored (Wh) = String Voltage × Total Ah across all parallel strings.

19" Rack-Mount vs Floor-Standing

Rack-mount battery cabinets (1U–9U) integrate with standard 42U server racks and typically hold smaller batteries (7Ah–42Ah). Floor-standing battery cabinets accommodate larger batteries (65Ah–200Ah) in a standalone enclosure suitable for large 3-phase UPS systems. Both types are available through Sukhai UPS.

Engineering

Battery Bank Design — What We Calculate

Proper battery bank design requires accurate engineering calculations. Sukhai UPS provides complete battery bank sizing as part of every project.

String Voltage Calculation

Determined by the UPS DC bus voltage (192V, 240V, 384V, 480V depending on UPS model and capacity). Number of 12V batteries in series = DC bus voltage ÷ 12V. This sets the string configuration.

Ah per String

Calculated from: (Load in kW × Backup Time in hours) / (DC Bus Voltage × Inverter Efficiency × Depth of Discharge 0.8). This gives the minimum Ah per string required. We select the standard battery size (65Ah, 100Ah, 150Ah, 200Ah) that meets or exceeds this requirement.

Number of Parallel Strings

If additional backup time is required beyond one string's capacity, additional parallel strings are added. For N+1 redundancy (data centre standard), one extra string beyond the minimum calculated is added so the bank can sustain full load backup even if one string fails.

Temperature Compensation

VRLA batteries deliver less capacity at lower temperatures. If the battery room may fall below 20°C, we apply a temperature derating factor and increase the calculated Ah requirement accordingly. This prevents undersized backup in cold seasons.

Intercell Connectors & Cabling

Battery-to-battery connectors (intercell links) must be correctly sized for the discharge current. Undersized connectors cause voltage drop and heating. We specify the correct cross-section copper conductors and stainless steel or lead-plated intercell connectors for each project.

Battery Monitoring

For large battery banks, we recommend individual battery monitoring systems (BMS/BIMS) that track per-cell voltage and temperature. Early warning of degraded cells prevents unplanned failure. Compatible with APC, Eaton, and most major UPS brands' remote monitoring platforms.

Applications

Battery Bank Applications

Data Centres

Standard requirement: 5–30 minutes backup at full UPS load. Battery banks sized to allow orderly shutdown or diesel generator start. External floor-standing battery cabinets for 3-phase UPS systems. Exide Powersafe or Quanta VRLA strings are most commonly specified.

View 3-Phase UPS →

Hospitals & Healthcare

Critical care UPS systems require 30–60 minutes of backup to ensure generator transfer before battery depletion. Hospital UPS battery banks use larger Ah strings (100Ah–200Ah) with N+1 redundancy and may include battery monitoring for life safety compliance.

Industrial Facilities

Process control systems, SCADA, and industrial automation UPS require battery banks tailored to the process shutdown time requirement. Industrial environments demand IP-rated battery cabinets and batteries rated for wider operating temperatures.

View Industrial UPS →
What We Supply

Battery Bank Solutions Available at Sukhai UPS

Floor-Standing Battery Cabinets

Standard and custom-height floor-standing battery cabinets in mild steel powder-coated enclosures. Designed for 65Ah, 100Ah, 150Ah, and 200Ah VRLA batteries. Available in 1-string to 4-string configurations per cabinet. Earthing studs, fusing, and cable glands included.

19" Rack-Mount Battery Units

Rack-mount battery extension units (EBMs) for single-phase UPS. Compatible with APC, Eaton, Emerson, and other major UPS brands. We supply both OEM-specified battery units and compatible third-party rack battery packs with matching connectors.

Exide / Quanta / Leoch VRLA Strings

We supply and install Exide Powersafe, Quanta (Amara Raja), Amaron, Leoch, and Panasonic VRLA battery strings for all battery bank applications. All batteries sourced through authorized channels with manufacturer warranty.

View Exide →

Custom Configurations

For non-standard UPS DC bus voltages or unusual space constraints, we fabricate custom battery cabinets and string configurations. Our engineering team handles the full project from battery sizing through to commissioning and final testing.

Installation Process

Battery Bank Installation by Sukhai UPS

Our end-to-end battery bank installation covers everything from site survey to commissioning.

Site Survey & Sizing

We visit the site, assess UPS model, DC bus voltage, available space, floor loading, and ventilation. We then produce a detailed battery bank sizing calculation with recommended battery type, string count, and cabinet layout.

Earthing & Safety

Proper earthing of battery cabinets and UPS interconnections is critical for safety and compliance. We install equipment earthing conductors per IS 3043 requirements and ensure RCBO/fuse protection for each battery string.

Battery Commissioning & Testing

After installation, we perform a complete battery commissioning: open-circuit voltage verification per cell, charge to float voltage, and a discharge test to verify backup time against the design specification. A commissioning report is provided.

View Installation Services →
FAQ

UPS Battery Banks — Frequently Asked Questions

A UPS battery bank is an external battery system connected to a UPS to extend its backup runtime beyond what the internal batteries provide. It consists of multiple VRLA batteries connected in series (to match the UPS DC bus voltage) and optionally in parallel (to increase total Ah capacity). Battery banks are housed in dedicated battery cabinets and are essential for data centres and industrial UPS systems requiring 10–60 minutes of backup time.
For a typical 20 kVA online UPS with a 240V DC bus and 15-minute backup at full load, you would need approximately 20 batteries in series per string (240V / 12V = 20 batteries) of approximately 65Ah each. For redundancy or longer backup, 2–3 parallel strings may be used. The exact calculation depends on UPS efficiency, load percentage, and desired backup time. Sukhai UPS provides free battery bank sizing calculations for your specific UPS model.
Rack-mount battery cabinets (19-inch) hold smaller batteries (up to 42Ah typically) and integrate with standard server rack infrastructure. They are ideal for data centre environments where everything is in racks. Floor-standing battery cabinets accommodate larger batteries (65Ah–200Ah) in a standalone enclosure. They are used for large 3-phase UPS systems (30 kVA+) where the battery bank is a separate physical unit adjacent to the UPS.
Standard VRLA battery banks in data centres are typically designed for a 3–5 year replacement cycle. With proper temperature control (20–25°C), annual impedance testing, and timely replacement of degraded strings, the battery bank supports reliable UPS operation. Li-ion battery banks can last 8–15 years, significantly reducing maintenance cycles. Sukhai UPS recommends annual battery health testing to identify and replace cells before they cause runtime shortfall or UPS failure.
In many cases yes. Most modern online UPS systems support multiple external battery packs. However, you cannot mix old and new batteries in the same string. The correct approach is either: (1) add a completely new parallel string of new batteries alongside existing strings, or (2) replace all strings simultaneously. Contact Sukhai UPS for an assessment of your specific UPS model's battery expansion options.
Related Solutions

Related Battery & UPS Services

SMF VRLA Batteries

Exide, Quanta, Amaron, Leoch VRLA batteries in all sizes for battery bank use. 7Ah to 200Ah, genuine manufacturer warranty.

View SMF Batteries →

Battery Testing Service

Annual battery bank impedance testing to identify degraded cells before they cause runtime failure. Recommended for all data centre battery banks.

Battery Testing →

UPS Installation Services

Complete UPS and battery bank installation — civil preparation, cabling, earthing, commissioning, and load testing. Sukhai UPS certified engineers.

Installation Services →