UPS Systems for Data Centers & Server Rooms

Online double conversion UPS, N+1 redundancy, modular UPS, and comprehensive AMC — everything your data centre needs to stay online, always.

Why Data Centres Need Online UPS

Server rooms and data centres have zero tolerance for power interruption. A power failure lasting even 20 milliseconds can crash servers, corrupt databases, and trigger hardware failures costing lakhs in recovery time.

Online double conversion UPS is the only UPS topology that provides true zero-transfer-time protection. Unlike offline or line-interactive UPS, online UPS continuously powers your load through its inverter — the mains supply feeds a rectifier which charges batteries and powers the inverter simultaneously. If mains fails, there is literally no switchover event because the load was already on the inverter.

Online UPS also regenerates clean, regulated power output regardless of what the mains supply delivers — protecting against voltage sags, swells, harmonics, frequency variations, and complete outages in a single unit.

View All UPS Systems
0 ms
Transfer Time
96%
Peak Efficiency (ECO mode)
800kVA
Maximum Capacity
9/9
Power Disturbances Covered

Critical Requirements for Data Centre Power

Modern data centres demand more than basic UPS. Here are the non-negotiable requirements and how we address each one.

Redundancy (N+1 / 2N)

No single point of failure. We design N+1 parallel UPS configurations — if one unit fails, the remaining units carry the full load without interruption. 2N (fully redundant) configurations are available for Tier III/IV data centres.

Scalability & Modularity

Modular UPS systems let you start with the capacity you need today and add power modules as your data centre grows — without replacing the cabinet or cabling. Pay for what you use, scale when you're ready.

Remote Monitoring (SNMP)

All our data centre UPS systems support SNMP network management cards, enabling real-time monitoring of UPS status, battery health, load levels, and alarms through your NMS or cloud dashboard — 24/7.

Hot-Swap Batteries

Battery replacement without shutdown. Our data centre UPS systems support hot-swappable battery modules, allowing battery maintenance and replacement while the UPS continues to protect your critical load.

Extended Runtime

Connect external battery cabinets to extend your runtime from minutes to hours. For data centres using diesel generator backup, even 10–15 minutes of UPS runtime is enough to safely allow generator startup and transfer.

Bypass & Safety

Static bypass switches allow load transfer to mains supply in microseconds during UPS overload or fault. Maintenance bypass panels allow complete UPS servicing without interrupting the connected load.

Data Centre UPS Systems We Supply

From edge server rooms to large hyperscale data centres, we supply the right UPS for every scale and requirement.

Online Double Conversion UPS

10 kVA – 800 kVA

Tower, rack-mount, and floor-standing three-phase online UPS for server rooms, edge data centres, and enterprise environments. Includes SNMP card slot, ECO mode, and parallel capability.

  • True online double conversion (VFI)
  • SNMP / Modbus / RS232 communication
  • External battery cabinet compatible
  • Parallel operation up to 4 units (N+1/N+3)

Modular UPS Systems

25 kW – 600 kW per frame

Modular UPS with hot-swap power modules for Tier II and Tier III data centres. Grow capacity by inserting additional modules without replacing the cabinet. Maximises uptime and lowers TCO.

  • Hot-swap power and battery modules
  • Scale in 25 kW / 50 kW increments
  • Intelligent load sharing across modules
  • Ideal for Tier II / III data centres

Recommended Brands for Data Centre UPS

We are authorised partners for India's leading data centre UPS brands. Each is engineered specifically for mission-critical environments.

Eaton 93PM

Scalable modular UPS, 25–1500 kW per frame. Industry-leading efficiency of 96%. Hot-swap modules, parallel-capable, and SNMP/Modbus ready. The benchmark for data centre UPS in India.

Learn about Eaton UPS
Vertiv Liebert APM

Modular 25–1500 kW with intelligent power module management. Lithium-ion battery option available for reduced footprint. Excellent for colocation and enterprise data centres across India.

Learn about Vertiv UPS
APC Symmetra

APC's flagship data centre UPS, 10–500 kW. Symmetra LX and Symmetra PX are proven in thousands of Indian data centres. Extensive service network, plug-in intelligence modules, and remote monitoring.

Learn about APC UPS

Automatic Transfer Switches & Bypass Panels

An Automatic Transfer Switch (ATS) monitors two power sources — typically mains utility and diesel generator — and automatically transfers the load to whichever source is available. In a typical data centre setup, the ATS sits between the generator and the UPS input, ensuring seamless switchover when mains fails and the generator starts.

Transfer time for a good quality ATS is under 100 ms, which is within the ride-through time of most online UPS systems — meaning your servers experience zero interruption even during a generator transfer event.

Maintenance bypass panels are equally critical — they allow you to take a UPS offline for scheduled maintenance while the load continues to run on raw mains power, with no shutdown required.

  • Open-transition ATS — breaks connection to source 1 before connecting to source 2
  • Closed-transition ATS — brief parallel connection, near-zero transfer time, ideal for data centres
  • Maintenance bypass panel — safely isolate UPS for servicing without load interruption
  • Static bypass — built into most online UPS; transfers load to bypass bus in microseconds during overload

Typical Data Centre Power Path

Mains Utility (Grid Supply)
Automatic Transfer Switch (ATS)
Online Double Conversion UPS
PDU / Distribution Panel
Servers, Storage, Networking
Generator connects to ATS as secondary source. Batteries cover the 10–15 s generator startup window.

Data Centre AMC — Keep Your UPS Ready When It Matters

A UPS that has never been tested is a UPS you cannot trust. Our data centre AMC plans ensure your protection is always ready to perform.

🔧

Quarterly Preventive Maintenance

Visual inspection, thermal imaging, connection tightening, firmware checks, battery voltage and impedance testing, and runtime verification — four times a year.

Annual Load Bank Testing

Full-capacity load bank test to verify that the UPS can handle 100% of rated load and maintain proper voltage regulation, waveform, and runtime under real conditions.

📞

Priority Emergency Response

Data centre AMC includes priority 4-hour emergency response SLA. Spare parts are stocked locally. Phone and remote support available 24/7 between scheduled visits.

Explore AMC Plans

Data Centre UPS FAQs

Online double conversion UPS is the best choice for server rooms. It provides zero transfer time (0 ms), pure sine wave output, and complete isolation of equipment from mains power disturbances. We recommend models from Eaton, Vertiv, or APC starting from 10 kVA for small server rooms, scaling up as needed.

N+1 redundancy means having one extra UPS unit (or module) beyond the minimum required to handle the load. If one unit fails, the spare automatically takes over without any interruption. For example, if your load requires 2 UPS units at full load, N+1 means you have 3 installed — giving you a failure buffer. 2N (fully redundant) means twice the required capacity, providing complete isolation between redundant paths.

Data centre UPS systems should undergo quarterly preventive maintenance including battery conductance testing, load testing, and firmware checks. A full load bank test is recommended annually to verify performance under 100% load. Our data centre AMC plans include all scheduled tests and provide documentation for compliance audits.

Yes. Modular UPS systems like the Eaton 93PM or Vertiv Liebert APM allow you to add power modules as your capacity grows, without replacing the entire system. You start with the frame and add modules in increments of 25 kW or 50 kW. This approach avoids over-provisioning costs at initial installation while ensuring you can scale when needed.

An Automatic Transfer Switch (ATS) monitors two incoming power sources — typically mains utility and a diesel generator — and automatically switches the load to the available source within milliseconds if the primary source fails. ATS is critical in data centres for seamless generator switchover, ensuring the UPS batteries don't deplete during the generator startup window (typically 10–20 seconds).

Get a Data Centre UPS Proposal

Share your data centre details — load, redundancy requirement, and site — and we'll prepare a full proposal including UPS sizing, ATS, bypass, and AMC.

  • Free site assessment
  • Detailed load calculation
  • Redundancy design (N+1 / 2N)
  • AMC pricing included